This products is suitable for high/low temperature adaptability tests for Electric, Electronic Instruments, meters and other products, spare parts and materials, in stock, transport and useing in high/low temperature environment.
Features:
Refrigeration Technique
Together with French “TECUMSEH”/ Germany “COPELAND” Expert of refrigeration, we designed and developed refrigeration plan to keep longer refrigeration and to be according to environment protection.
By regular refrigeration technique, it is easy to satisfy different grade test temperature request, such as -20~+150degrees, -40~+150degrees, -60~+150degrees, -70~+150degrees etc.
By liquid Nitrogen refrigeration technique, we can satisfy -180degrees ~+150degrees
Chamber humidity controlling technique
Special structure design of chamber, with high quality import temperature, humidity sensor and controlling meter, can be sure of precise of temperature and humidity, it makes easy to control test temperature deviation, and also we can enhance the precise controlling by your request.
Control System
Operation automatically, simply is the tendency of our control system design, by this you could spend much more time in test result research of testing result.
By many steps program controlling, we can satisfy different complex testing requests.
Process
Following international standard, our products get up to international quality.
Regular Technical data
Temp.Fluctuation:±0.5degrees (As request it can be 0.1degrees)
Temp.Uniformity:≤2.0degrees (As request it can be 0.1degrees)
Temp.Warp:±2.0degrees (As request it can be 0.1degrees)
Heat Up Time: 2-3degrees/min (As request it can be 10degrees)
Pull Down Time :1-1.5degrees/min (As request it can be 10degrees)
Size:(D*W*H)
Model
Internal Dimensions(mm)
External Dimensions (mm)
SGDP-50
320*350*450
790*800*1320
SGDP-100
500*400*500
970*850*1370
SGDP-150
500*500*600
970*950*1470
SGDP-250
520*630*780
1060*997*1740
SGDP-500
700*800*900
1182*1250*1880
SGDP-800
800*1000*1000
1250*1500*1930
SGDP-010
1000*1000*1000
1450*1500*1930
(The size can be designed according to your request)
Standard and Test Methods
GB11158 High temperature test chambers technical conditions
GB10589 Low temperature test chambers technical conditions
GB10592-89 High/Low temperature testing chambers technical conditions
GB/T2423.1-2001Low temperature chambers technical testing methods
GB/T2423.2-2001High temperature chambers technical methods
GB/T2423.22-2001 Temperature changes testing methods
GJB150.3 High temperature Test
GJB150.4 Low temperature Test
And other National test standard.
Safety Protection
Safety configuration: Current discharge protection,Circuit break protection, Compressor over load protection, Fan over load protection, Over temperature protections, Phase sequence/ Short phase protection.